Off To Shandong: 9 SCB11 Dry Type Transformers Are On Their Way

Sep 05, 2025

Leave a message

 

 

Introduction

This series strictly complies with national standards and boasts advantages including reliability, high efficiency, environmental friendliness, and minimal maintenance. They are ideal choices for industrial and commercial power systems.

SCB11 Series Dry Transformer

 

Specification

Model

Quantity

Accessories

SCB11-630/10/0.4

2

Cooling Fans, Temperature Controller with RS485 Interface, Stainless Steel Enclosure 1700 x 1400 x 2200 mm, Bottom Protective Grille, Electromagnetic Locks, Dual Limit Switches

SCB11-800/10/0.4

2

Cooling Fans, Temperature Controller with RS485 Interface, Stainless Steel Enclosure 1800 x 1400 x 2200 mm, Bottom Protective Grille, Electromagnetic Locks, Dual Limit Switches

SCB11-1000/10/0.4

1

Cooling Fans, Temperature Controller with RS485 Interface, Stainless Steel Enclosure 1800 x 1500 x 2200 mm, Bottom Protective Grille, Electromagnetic Locks, Dual Limit Switches

SCB11-1250/10/0.4

4

Cooling Fans, Temperature Controller with RS485 Interface, Stainless Steel Enclosure 1900 x 1500 x 2200 mm, Bottom Protective Grille, Electromagnetic Locks, Dual Limit Switches

 

Manufacturing

 

Materials

 

01

Material Preparation

*Perform electromagnetic calculations and structural design based on technical requirements.

*Prepare core materials, including silicon steel sheets, enameled wires, insulating materials, bobbins, and enclosures.

Core

 

02

Core Processing

*Slitting: Cut silicon steel coils into strips according to design specifications.

*Stacking: Laminate silicon steel sheets crosswise to form a core of specified shape and size, in order to reduce eddy current loss.

Winding

 

03

Coil Winding

*Winding: Wind enameled wires tightly onto the bobbin using a winding machine according to specified turns and layers.

*Lead attachment: Solder winding leads to terminals, and ensure proper insulation and securing.

Assembly

 

04

Insulation & Assembly

*Treatment: Wrap finished coils with insulating paper, tape, etc., to ensure sufficient insulation strength.

*Assembly: Insert coils into the core and fasten them to form a complete transformer unit.

 

Curing

 

05

Vacuum Impregnation

*Pre-drying: Place the assembled transformer units in an oven to remove moisture.

*Impregnation: Put the units into a varnish tank, evacuate the air, and then inject insulating varnish.

*Curing: Remove the units and bake at high temperature to cure the varnish.

Final Assembly

 

06

Final Assembly & Wiring

*Install the impregnated and cured units into enclosures.

*Weld input/output terminals, and install auxiliary components such as fuses and indicator lights.

Testing

 

07

Testing

Turns Ratio Test

Dielectric Withstand Test

Resistance Test

No-Load Losses Test

Load Losses Test

Final Inspection

 

08

Final Inspection & Packaging

Appearance Inspection: Check for scratches, stains, and correct labeling.

Performance Sampling Test: Conduct key electrical tests again.

Packaging: Use shock-absorbent and moisture-proof materials to ensure safe transportation.

 

Promise

 

As the truck departs, we are thinking not only completing an order, but also honoring the trust the customer has placed in us for the years to come. When you buy from us, you get more than a transformer; you get our promise to be there when you need us. We're here to make things reliable and easy for you.