Introduction
The VKE 11kV distribution transformer has achieved global recognition for its excellent thermal performance, outstanding insulation capabilities, and exceptional resistance to harsh weather conditions.
Successfully implemented across demanding African markets, the series has proven its reliability in extreme climates, delivering stable operation and playing a vital role in supporting the upgrade and expansion of local power infrastructure.
Specifications
| Input Voltage: | 11kV |
| Output Voltage: | 0.4kV |
| Capacity Range: | 30~2,500kVA |
| Frequency: | 50Hz |
| Installation: | Outdoor/Indoor |
| Altitude: | ≤ 1,000m |
| Ambient Air Temperature: | -25°C ~+40°C (Average: +20°C) |
Our operator is inspecting every detail of the core to ensure flawless performance.

Features
- Low-voltage windings with capacities ranging from 630 to 2,000 kVA adopt cylindrical or helical structures, providing enhanced mechanical strength and improved short-circuit resistance.
- A positioning structure is incorporated to prevent component displacement during transportation. All fasteners are fitted with locking nuts to ensure long-term operational stability and prevent loosening.
- The surface undergoes a comprehensive treatment process, including degreasing, derusting, and phosphating, followed by the application of primer and topcoat. This ensures excellent corrosion resistance and reliable performance in harsh environmental conditions.
- Multiple protective devices, including gas relays, pressure relief valves, and oil level gauges, are equipped to ensure safe, stable, and reliable transformer operation.
Our technician is assembling the key components

Custom Options
Electrical Parameter
- Voltage Level: input voltage, output voltage, tapping range
-Capacity: overload capacity, special capacity
-Frequency: 50Hz, 60Hz
Structure
-Winding Configuration: copper or aluminum conductors, insulating materials, vector group
-Cooling System: oil natural air natural (ONAN), oil natural air forced (ONAF), special cooling design (for tropical zones)
Mechanical & Environmental Resilience
-Protection Grade: IP54, IP65, corrosion-resistant treatment (for coastal areas)
-Special Climate Condition: highland (altitudes>1,000m), extreme temperature (-40℃~+50℃), earthquake-resistant design (for seismic zones)
Accessory
-Bushings: porcelain or composite bushings
-On-Load Tap Changer (OLTC)
-Color & Logo
Our quality inspector is conducting precision testing 
Technical Q&A on 11kV Distribution Transformer
Q: What are the key points to pay attention to during installation?
A: • Stable foundation, horizontal installation, no tilting
• Adequate heat dissipation space (e.g., ≥ 1.5m from walls)
•Ground resistance ≤ 4Ω
• Checks: oil level, sealing and cleanliness of the enclosure
Q: What causes abnormal temperature rise?
A: • Prolonged overloading
• Cooling system failure (fan or oil pump shutdown)
• Oil circuit blockage or insufficient oil volume
• Internal short circuit or poor contact
Q: How to handle oil leakage?
A: • Minor Leaks: Tighten bolts or replace gaskets
• Severe Leaks: Shut down the equipment, drain the oil, and repair or replace components